Direct Acting Control Solenoid Valve Water Solenoid Valve Fd-4

Solar Automatic Water Solenoid Valve Item No. : FD-4In automatic circuit or infrared control system, Solenoid valve applied in automatic control system, such as pipe of public water work project, sensor shower, solar heater water self-motion, washing machine, sensor sanitary ware, shower, garden irrigation, prepayment water

Featured Products

Solar Automatic Water Solenoid Valve 
Item No. : FD-4



In automatic circuit or infrared control system, Solenoid valve applied in automatic control system, such as pipe of public water work project, sensor shower, solar heater water self-motion, washing machine, sensor sanitary ware, shower, garden irrigation, prepayment water.
 



Technical Feature FD series
Instruction

 
Rate voltageAc12VDC 12VAC24VDC 24VAC 110VAC 220V
Coil resistance25Ω ±2Ω(20ºC)36Ω ±2Ω(20ºC)75Ω ±5Ω(20ºC)130Ω ±5Ω(20ºC)1.7kΩ ±0.1KΩ(20ºC)4.75kΩ ±0.25KΩ(20ºC)
Min current320mA300mA288mA166mA36mA18mA
Switch modeAC and DC continuous
Operating pressure0.02Mpa-0.8Mpa
Media temperature1ºC--75ºC
Responding timeOpen ≤0.15s close≤0.5s
Service life≥1000000 cycles

Performance test
Strength testStatic pressure 1.6MPaWithstand voltage pressure 1.2MPa/5min
No-load testVoltage V*0.9Permissible limiting voltage V*1.15
High water pressure start and closeAt water pressure 0.8MPa,voltage*0.9,the solenoid valve can be started and closed normally
low water pressure start and closeAt water pressure 0.02MPa,voltage*0.9,the solenoid valve can be started and closed normally
Leakage upon high water pressure1.2MPa without leakage
Leakage upon low water pressure0.02Mpa leakage≤0.1ml/min
Electric strengthAmong conductive part, mounting hole and nonconductive metal, it can withstand 1500V/50Hz,leakage current 0.75mA for 1 min without the breakdown
Insulation resistanceThe resistance between the charged part and nonconductive metal part tested by megohm meter of 500V ≥100MΩ
 
 
 
Sealing test
 
 
 
Static pressure
AirHigh pressure1MPa
Low pressure0.02MPa
Cold waterHigh pressure1.2MPa
Low pressure0.02MPa
Hot waterHigh pressure0.8MPa
Low pressure0.02MPa
Service life≥1000000 cycles(CJ/T 194-2004)
      
 
Requirements of working environment
Temp of working environment1ºC--60ºCPermissible limiting pressure(water)≤1.2MPa
Humidity of working environment35%-90% RHMounting directionIt is mounted in vertical. The inclination do not exceed 15 degrees
Storage temp-5--80ºC( no freezing state)Storage humidity25%--95% RH(No condensation state)






Application:
Direct Acting Control Solenoid Valve Water Solenoid Valve Fd-4

Direct Acting Control Solenoid Valve Water Solenoid Valve Fd-4Direct Acting Control Solenoid Valve Water Solenoid Valve Fd-4Direct Acting Control Solenoid Valve Water Solenoid Valve Fd-4
About Fuxin : 
Direct Acting Control Solenoid Valve Water Solenoid Valve Fd-4Direct Acting Control Solenoid Valve Water Solenoid Valve Fd-4


 

Contact us